THE DP50RB DIARIES

The Dp50rb Diaries

The Dp50rb Diaries

Blog Article

Assistance 4D probe; figure out the probe by using the ID code; switch the 4D push signal by means of the  electrical relay to create the 4D probe operate Ordinarily. four.two.two Main board The key board may very well be divided into two parts: front-finish of the key board and again-finish of the key board.

Greatest 4 periods tasking for one particular transmitted beam, resulting in fantastic time resolution and better frame rate.

Get an entire and prolonged watch with the anatomical construction by means of panoramic imaging coupled with velocity sign and ahead/backward scan potential building scanning easier, smoother plus much more controllable.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

Reduce off cable ties connecting the main unit around the Show by diagonal reducing pliers, and afterwards pull out the corresponding cable plugs.

Content material System Test the battery periodically : a) Examine if battery could be billed Generally when electric power-on: That The present ability is one hundred% or potential improves immediately after a short time signifies which the battery might be charged Commonly.

Site 145 Cleanse control panel Instruments: dry gentle cloth, moderate soapy water  System:  Use dry gentle cloth to wash the surface area of your program. Should the program is filthy, moisten the soft cloth with gentle soapy drinking water and wipe off any stains. Use dry tender cloth to remove any dampness and allow all really hard surfaces to completely air-dry. Website page 146: Thoroughly clean The Peripherals

Find better diagnostic data via prolonged check out on the anatomical composition on all convex probes.

Permits utilization of multiple scanned angles to sort just one graphic, leading to Increased distinction resolution and enhanced visualization

five.two.3 Geometric positioning accuracy Longitudinal geometric positioning accuracy  Examination Move: Do changes as the way in which in screening the most depth. Record the distance by 20mm Every single section over the longitudinal targets line utilizing the measurement caliper; Choose the value with the greatest error (to 20mm), determine the accuracy using the components under The measurement caliper needs to be positioned on the upper fringe of the target, Be aware:... Site seventy nine Transverse geometric positioning accuracy  Examination Phase: Protect the scan floor on the phantom with drinking water or couple gel, gently contact the probe Using the scan surface Regulate the depth, earning the transverse targets to generally be exhibited while in the picture. Adjust the main target place to get posited beside the transverse targets (the common just isn't distinct) Regulate parameters like get, TGC, producing Each and every transverse targets to be Plainly displayed. Web site 80 five.5.two.four Blackout Place Check Move: Protect the scan surface with the phantom with water or pair gel, Carefully Speak to the probe With all the scan area Alter the depth in a reduce price, and established the main target at the nearest location to the scan area. Reduce the worth of parameters like AP, Gain until eventually the background noise just is often seen. Website page eighty one: Software Update And Servicing

Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.

Observe: Right before uploading the log, be certain the ultrasound procedure has long been linked to network, in any other case, the method might alert “couldn't connect to server” The server (smtp.

Cookies are important to the appropriate operating of a site. To help your working experience, we use cookies to keep in mind log-in specifics and supply safe log-in, collect data Dp50rb to optimize web page features, and deliver information tailor-made towards your passions.

Soon after replacing the CPU module, vital file should be generated once again according to the new MAC handle and penned into HDD on the device. Or else, the configuration purpose from the product or service will be missing. Soon after eradicating the CPU module, Eliminate panhead screws with washers (12 M3X6) set on the key unit box, you will take off the board. Webpage 118 Figure 8-29 Disassemble the Control Panel Assembly (one) Hold the higher fringe of control panel assembly, and open up the control panel. Determine 8-thirty Disassemble the User interface Assembly (two) Immediately after eradicating a single countersunk head self-tapping screw PT3X10 fastened within the user interface and take out the plug from the keyboard and the most crucial unit connecting cables, you could potentially clear away the control panel assembly.

A sensible new condition, Increased mobility and effortless Procedure make DP-fifty compatible for all medical options.

Report this page